ChannelPlus Telephone Entry Module
SAFETY INFORMATION:
OpenHousetm modules
attach from the top
IMPORTANT INSTRUCTIONS
When using your telephone equipment, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to persons, including the following:
a) Never install telephone wiring
during a lighting storm.
1) Hook from the top
2) Swing into place
3) Push button to lock
b) Never install telephone jacks in wet
locations.
1. Read and understand all instructions
1
2. Do not use this product near water, for example, near a bath
tub, wash bowl, kitchen sink, or laundry tub, in a wet
basement, or near a swimming pool.
c) Never touch uninsulated telephone
wires or terminals unless the
telephone line has been disconnected
at the network interface.
3. Never push objects of any kind into this product through
cabinet slots as they may touch dangerous voltages.
Telephone Master Hub (4 lines x 6 phones)
ChannelPlus model H616
3
From
Telco
Expansion
Ports
Telephones
R
T
RJ31X
4
3
2
1
R
T
R
T
Out
R
T
d) Use caution when installing or
modifying telephone lines.
4. SAVE THESE INSTRUCTIONS
2
Wire Color Codes
The H612 Telephone Entry Module provides a superior method
of telephone connection to your system. Each unit provides
surge suppression for two lines and a master disconnect. Also,
Solid Color
Twisted-Pair Wire
RING
TIP
brown
pair 4
Cat5
4 pair UTP
brown/white
blue
RING
TIP
green
pair 3
each line has an LED
status indicator to warn
you of a surge event.
white
pair 3
green/white
Telephone Entry Module (surge,disconnect)
yellow
ChannelPlus model H612
RING
TIP
orange
pair 2
From NTE
Line 2
black
pair 2
orange/white
1
2
3
6
5
4
Telephone
Output
red
Disconnect
Out
Surge
Warning
Expansion
Output
In
RING
TIP
pair 1
pair 1
blue
Line 2
green
2
2
3
blue/white
5
Line 1
6
5
4
1
2
3
1
2
3
5
Modular connectors
Line 1
8 position connectors
PR2
PR3 PR1 PR4
6 position connectors
PR3
PR2
PR1
PR2
PR1
T R T R T R T R
1
PR1
R T
2
3
4
5
6
7
8
Typical Installation
T R T R
2
T T R T R R
5
1
2
3
4
5
6
1
3
4
5
6
1
2
3
4
6
Each line is individually surge protected to 50 Joules and
RJ-11
RJ-14
Dual line telephones &
answering machines
RJ-25
Rare
3 line KSU
Install this jumper for normal
operation. Remove to disconnect
telephone service from the system.
4000 Amps. Some surges contain sufficient energy that
although your system has been protected, the surge
circuit will be unable to provide additional protection.
When this happens, the red light for that line will turn on
and the module needs to be returned for service.
Single line telephones,
answering machines &
modems
RJ-45 (wired to TIA T568A standard)
Ethernet (both 10BaseT and 100BaseT)
Structured wiring of phones and data lines
(There are other wiring standards. For
residential use, we recommend that RJ-45
jacks be wired to the T568A standard.)
CAT-5 jumper
(included)
Wiring a 110 connector
110 punch down tool
elepEntry Module (surge,disconnect)
ChannelPlus model H612
H612
The 110 is a sophisticated insulation
displacement connection system. To
push the wire between the contact
blades, use only a 110 punch down
tool. Using a screwdriver or needle
nose pliers may not seat the wire
properly and can damage the contacts.
From NTE
Line 2
Keep sheath close to connector
Untwist .5” max.
1
2
3
6
5
4
Disconnect
Out
Surge
Warnin
Expansion
Output
Telephone
Output
In
Line 2
2
2
3
5
Line 1
6
5
4
1
2
1
2
3
5
From telephone
company exchange
2 lines
Line 1
Note order of colors
2 lines to telephone
wall plates.
Wiring a Cat-5 jack
H618 telephone
expansion hub
2
1
3
Telephone Expansion Hub (4 lines x 8 phones)
ChannelPlus model H618
110 puunch-
down tool
Line
2
1
2
3
Expansion
Ports
Telephones
5
Line
R
T
4
In
2
3
5
Keep sheath
close to jack.
R
T
3
2
1
R
T
Use self adhesive
sticker provided to
label the output I.D.
Out
Follow color code for T568A jacks.
R
T
Position first pair to channel closest
to end of jack. (Do not untwist
conductor pairs more than 0.5"
from the termination point.)
Using a 110 punch-down tool,
push wires into channels and trim.
Repeat for subsequent pairs.
When all conductor pairs are
terminated, snap on strain relief caps.
Colors of OpenHousetm wiring
Wiring Modular Plug (T568A)
Use CAT-3 or CAT-5
wires, 2 lines to 8
telephone wall
1
4
CAT-5, 4 UTP
RG-6 coax
2
5
3
6
Telephone
(from telco)
Insert wires in this order:
White/Green
Green
White/Orange
Blue
Telephone
(in house)
Downstream/External
(to TVs)
White/Blue
Orange
White/Brown
Brown
Data
1
2
4
5
3
6
Security
Upstream/Internal
(from modulators)
|